Fire Guard - Professional Fire Safety Solutions
+91 7202099697 perfectagni@gmail.com

Water Spray Systems

High Velocity & Medium Velocity Water Spray Fire Protection Systems for Industrial Applications

Advanced Fire Protection Technology

High Velocity and Medium Velocity Water Spray Systems are specialized fire protection systems designed to extinguish fires involving flammable liquids with flash points of 65°C (150°F) or higher. These systems employ three principles of extinguishment - emulsification, cooling, and smothering - to effectively control and extinguish fires within seconds.

System Overview

High Velocity System

Designed for high-risk areas with flammable liquids, providing rapid fire suppression through water emulsification.

  • For high flash point liquids
  • Emulsification principle
  • Rapid fire suppression
  • High pressure operation

Medium Velocity System

Ideal for general fire protection applications with moderate risk flammable liquids and electrical equipment.

  • Versatile applications
  • Cooling & smothering
  • Moderate pressure
  • Wide coverage area

Automatic Detection

Integrated detection systems for automatic activation and rapid response to fire emergencies.

  • Heat detection
  • Smoke detection
  • Flame detection
  • Manual override

Comprehensive Fire Protection

Water Spray Systems provide robust fire protection for high-risk industrial facilities. The systems are designed to create a dense water curtain that cools the surface, forms an emulsion with burning liquids, and creates a steam blanket that smothers the fire. This multi-pronged approach ensures effective fire control even in challenging industrial environments.

Key Features & Benefits

Rapid Fire Suppression

Extinguishes fires within seconds through simultaneous cooling, emulsification, and smothering actions, minimizing damage and downtime.

High Reliability

Engineered for industrial environments with robust components, redundant systems, and fail-safe operation for maximum reliability.

Automatic Operation

Integrated detection and control systems enable automatic activation, ensuring immediate response to fire emergencies.

Versatile Applications

Suitable for various industrial applications including transformers, oil-filled equipment, flammable liquid storage, and process areas.

Technical Specifications

System Performance Data

Comprehensive technical specifications ensuring reliable performance under various conditions:

  • Operating Pressure: 7-10 bar (HV), 3.5-7 bar (MV)
  • Water Flow Rate: As per hazard requirements
  • Response Time: < 30 seconds
  • Coverage Density: 10-20 LPM/m²
  • System Activation: Automatic/Manual
  • Pipe Material: Galvanized/GI/Stainless Steel

System Comparison

Parameter High Velocity System Medium Velocity System
Operating Pressure 7-10 bar 3.5-7 bar
Nozzle Type Projection Nozzles Spray Nozzles
Application High Flash Point Liquids Moderate Risk Areas
Extinguishing Principle Emulsification Cooling & Smothering
Coverage Pattern Concentrated Wide Area
Response Time < 30 seconds < 45 seconds

Application Areas

Transformers & Switchgear

Protection for oil-filled electrical transformers, circuit breakers, and switchgear rooms against fire hazards.

Flammable Liquid Storage

Storage tanks, loading areas, and processing units handling flammable liquids with high flash points.

Process Equipment

Pumps, compressors, reactors, and other process equipment handling hazardous materials.

Industrial Machinery

Large industrial machines, turbines, generators, and other critical equipment requiring fire protection.

Technical Data Sheet

Component Specification Standard
Piping Material Galvanized Steel/Stainless Steel IS 1239 / ASTM A53
Nozzle Material Brass/Stainless Steel IS 9523 / NFPA 15
Detection System Heat/Smoke/Flame Detectors IS 2189 / NFPA 72
Control Panel Automatic with Manual Override IS 5572 / NFPA 70
Water Supply Dedicated Storage & Pumps IS 3844 / NFPA 20
System Pressure As per Design Requirements NFPA 15 / OISD 116

Installation Process

1

Site Assessment

Comprehensive risk assessment and hazard analysis to determine system requirements, coverage areas, and design parameters.

2

System Design

Detailed engineering design including hydraulic calculations, nozzle placement, pipe routing, and control system integration.

3

Installation

Professional installation of piping, nozzles, detection systems, control panels, and water supply infrastructure.

4

Testing & Commissioning

Comprehensive testing, performance verification, and commissioning to ensure system reliability and compliance.

Industry Applications

Power Generation

Thermal power plants, hydroelectric stations, and renewable energy facilities with critical electrical equipment protection needs.

Oil & Gas

Refineries, petrochemical plants, offshore platforms, and storage terminals with flammable liquid hazards.

Chemical Industry

Chemical processing plants, manufacturing facilities, and storage areas with fire and explosion risks.

Manufacturing

Industrial manufacturing plants, automotive facilities, and processing units requiring reliable fire protection.

Safety & Compliance

Regulatory Compliance

Our Water Spray Systems comply with international fire safety standards including NFPA 15, OISD 116, IS 2189, and other relevant codes. Each system is designed, installed, and tested to meet or exceed regulatory requirements, ensuring optimal protection for your facilities and personnel.

Need Professional Fire Protection?

Contact our experts for a comprehensive assessment and customized water spray system solution for your facility.

Request Consultation
Loading...